Policy topic

Indoor Air Quality

Provisions (9)

CA
STD.5.1Indoor Air Quality

CALGreen MERV 13+ filtration and continuous ventilation

Title 24 Part 11 requires MERV 13 or better filtration for new or replacement HVAC and continuous ventilation.

California — State Roles and Responsibilities for PK-12 Public School Facilities — 2025 State Profile (2025), printed p. 54 · Cal. Code Regs. tit. 24, pt. 11

AZ
STD.5.1Indoor Air Quality

Classroom HVAC systems must maintain prescribed carbon dioxide levels

General education, science, and art classrooms must have HVAC systems capable of maintaining carbon dioxide concentrations no greater than 800 parts per million above outdoor ambient levels.

Arizona State Roles and Responsibilities for PK-12 Public School Facilities (2025), printed p. 32 · A.A.C. R7-6-215

CA
STD.5.1Indoor Air Quality

Health and Safety Code § 39930 et seq. program authority

Health and Safety Code § 39930 et seq. provides program authority related to indoor air.

California — State Roles and Responsibilities for PK-12 Public School Facilities — 2025 State Profile (2025), printed p. 54 · Cal. Health & Safety Code §§ 39930 et seq.

AZ
STD.5.1Indoor Air Quality

New school designs must incorporate construction-phase indoor air quality practices

New school construction must incorporate indoor air quality practices based on the SMACNA Indoor Air Quality Guidelines for Occupied Buildings Under Construction to minimize contaminants during and after construction.

Arizona State Roles and Responsibilities for PK-12 Public School Facilities (2025), printed p. 32 · A.R.S. § 41-5832; SMACNA Indoor Air Quality Guidelines for Occupied Buildings Under Construction

AL
STD.5.1Indoor Air Quality
Confirmed absent in profile

No Statewide Routine Indoor Air Testing Requirement

Alabama does not require routine indoor air testing or specific operational HVAC filtration or ventilation benchmarks for public K-12 schools.

Alabama State Profile (2025), printed p. 34

AZ
SUP.10Guidance & Publications

School Facilities Division must provide updated indoor environmental quality information

The School Facilities Division is required to provide school districts with updated information on maintaining indoor environmental quality at least once every two years, including technical guidance and best practices for maintaining healthy school environments.

Arizona State Roles and Responsibilities for PK-12 Public School Facilities (2025), printed p. 18 · A.R.S. § 41-5702(A)(8)

AZ
STD.5.2Ventilation

School HVAC systems must meet applicable ASHRAE Standard 62 ventilation requirements

School HVAC systems must meet or exceed the version of ASHRAE Standard 62 applicable when the system was installed and must be maintained to provide continued indoor air quality performance.

Arizona State Roles and Responsibilities for PK-12 Public School Facilities (2025), printed p. 32 · A.R.S. § 41-5832; ASHRAE Standard 62

AZ
CMP.8Facility Assessment

Schools must test a sample of classrooms for carbon dioxide compliance

Carbon dioxide testing must be performed at a work surface near the center of the classroom under normal occupancy conditions, with at least 10 percent of classrooms in each building randomly sampled.

Arizona State Roles and Responsibilities for PK-12 Public School Facilities (2025), printed p. 32 · A.A.C. R7-6-215

Prototype research tool. Records are normalized from NCSI state profiles and have not been verified against current statutes or regulations. This is not legal advice — consult primary legal sources for current requirements.